Environmental Testing Equipments

Leading Manufacturers, Exporters and Wholesaler of BOD Incubator, Corrugation Lab CMT Tester, Digital Humidity Meter, Environmental Chamber, Lab Hot Oven, Muffle Furnace, PAP-5053 Laboratory Hot Air Oven, Paper Ink Proofing Kit, Paptech Laboratory Hot Air Oven and Water Soil Analysis Kit from Jaipur.

75,000.00 / Piece

1 Piece (MOQ)

Get Best Price
Business Type Manufacturer, Exporter, Supplier
Chamber Volume (Litre) 300 Litre
Temperature Range 5 to 75 degree celsius
Accuracy +/- 0.05 Degree C
Model PAP- 5051
Display Type Digital
Brand Pap-Tech
Temperature range 5°C to 50°C
Origin India
Brochure View

Click to view more

Preferred Buyer From

Location Worldwide

Description:

It is used for BOD Incubator samples of effluent and others. Double walled, heavily insulated. Automatic control & double door construction. Controlled by digital temperature controller inner stainless steel. Outer body ms duly powder coated/ stainless steel. The inner chamber is properly insulated with special grade puf to prevent thermal losses. Air circulating fan for uniform temperature.

Temperature range :5°C to 50°C.

 

Accuracy ±0.5°C.

Features:

  • CFC Free Compressor.
  • Full View Inner Glass Door.
  • Lock And Key Arrangement.
  • Caster Wheel Mounted Cabinet
Read More...


Yes! I am interested


1.75 Lac / Piece

1 Piece (MOQ)

Get Best Price
Business Type Manufacturer, Exporter, Supplier
Material Metal
Sample size 0.5 inch x 6 inch
Brand Pap-Tech
Application Laboratory Use
Power Source Electric
Origin India
Brochure View

Preferred Buyer From

Location Worldwide

Description:

A laboratory corrugating machine with digital temp. Controller for producing a sample to evaluate flat crush resistance of corrugating medium. 'A' fluting rolls are heated up to 176° C and maintained with a constant digital temperature controller. Standard model available with 'A' flute.

   Sample size 0.5 inch x 6 inch 

Read More...


Yes! I am interested


4,000.00 / Piece

1 Piece (MOQ)

Get Best Price
Business Type Manufacturer, Exporter, Supplier
Voltage 50 Cyles Preferably From A CVT
Display 3/2 LEDS (for Humidity As Well As Temperature
Model PAP-5058
Brand Pap-Tech
Dimensions 220x160x150mm (approx)
Weight 5.5 kg
Temperature Range 0-100 Degree C
Power Consumption 0.48 unit / 12 hrs
Current Rating 0.18 amp
Wattage 40 W
R Humidity 0-99%
Sensor Philips H1/lm-35

Click to view more

Preferred Buyer From

Location Worldwide

Description:

Digital Humidity Meter indicates Ambient Humidity to an accuracy of about ± 2% ranging from zero to hundred percent. An imported versatile Phillips H1 sensor is used together with digital circuitry to measure, calibrate and store the data before displaying it on to the 3½ digit LEDS. Ambient temperature is also measured by LM-5 and displayed simultaneously on 3½ digit LEDS.

Features:

  • Displays humidity to ± 2% and temperature to ± 10.C simultaneously.
  • Large storage RAM (16K) for Data Acquisition and Computer downloading using timer control.
  • Direct interface with any computer (RS. 232C).
  • Software for analyzing and graphically displaying data.
  • Built-in regulated power supply with optionally battery backup
Read More...


Yes! I am interested


1.10 Lac / Piece

1 Piece (MOQ)

Get Best Price
Business Type Manufacturer, Exporter, Supplier
Brand Pap-Tech
Model Number PAP-5052
Accuracy +/-3%
Inner Chamber Dimension 355x355x355 mm, 700x450x450mm
Working Temperature 10-60 degree C
Humidity Ranges 30-90%.
Origin India
Brochure View

Click to view more

Preferred Buyer From

Location Worldwide

Description:

A sample of a paper or board is conditioned and saidto be in equilibrium with the conditioning atmosphere when it has been exposed to the atmosphere long enough for the result of two weighings of a test piece,per formed at and interval of at least 1 hour. This method is suitable for conditioning of all type ofpaper and board before and during testing.

 

Technical Specification:

  • A sample of a paper or board is conditioned and said to be in equilibrium with the conditioning
  • Atmosphere when it has been exposed to the atmosphere long enough for the result of two weighings
  • Of a test piece and interval of at least not to differ by more than 0.25 per cent.
  • This method is suitable for conditioning of all type of paper and board before and during testing.

Option:

Digital Temperature indicator cum controller

Read More...


Yes! I am interested


35,000.00 / Piece

1 Piece (MOQ)

Get Best Price
Business Type Manufacturer, Exporter, Supplier
Country of Origin India
Material Stainless Steel
Model Name/Number PAP-5053 - B
Max Temperature +10~300deg C
No Of Chamber One
Brand PAP-TECH
Number Of Shelves 2
Size 18x18x18
Temperature Range 50-300 Degree Celsius
Usage/Application Laboratory
Brochure View

Click to view more

Preferred Buyer From

Location Worldwide

Description:

Lab Hot Oven:

It is used for moisture determination of pulp,paper,and paperboard etc.

Double walled & heavily insulated.

Read More...


Yes! I am interested


30,000.00 / Piece

1 Piece (MOQ)

Get Best Price
Business Type Manufacturer, Exporter, Supplier
Max Temperature (Degree Celsius) 800-900,1000-1100,900-1000,Upto 1100 Degree Celcius
Material Loading Capacity 500-1500 kg
Model No. PAP-5054
Brand Pap-Tech
Muffle Size 4 x 4 x 9 Inch
Max Load Rating 7.5 KW
Features High performance, Durability, Reliable

Preferred Buyer From

Location Worldwide

Description:

Muffle Furnace:

 Muffle Furnace is used for incineration of solids. Temperature range up to 1000°C Working temperature 930° C Temperature controlled by energy regulator complete with Pyrometer and Thermocouple. Digital temp controller can be mounted on top side also.

 

Option:

Digital temperature indicator-cum controller.

 

Features:

  • High performance
  • Durability
  • Reliable

Other Details:

  • Castings are made of thick mild sheet reinforced with iron angles and painted with powder coating.
  • Heating chamber consisting of regular horizontal shape totally enclosed muffle baked at 1200 ºC.
  • Heating element meter made of kanthal wire.
  • Light ceramic insulation provided into furnace body.
  • Furnace are equipped with dependable indicator pyrometer having a scale calibrated in 25 increments at 1000º C.
  • Silver fuse is provided to protect the heating elements pyrometer.
  • Pyrometer is equipped with chrome alumel thermocouple.
  • Furnace can be operated continuously up to 900º C.
Read More...


Yes! I am interested


30,000.00 / Piece

1 Piece (MOQ)

Get Best Price
Business Type Manufacturer, Exporter, Supplier
Material Inside Chamber Stainless Steel
Usage/application Laboratory Uses
Model Name/Number PAP-5053
Temperature Range 50-250 Degree Celsius, 50-300 Degree Celsius
Body Material MS
Brand Pap-Tech
Number Of Shelves 2
Display Type Digital
Accuracy Of Thermostat +/- 1 Deg C to 2 Deg C or less.digital
Origin India

Click to view more

Preferred Buyer From

Location Worldwide

Description:


Laboratory Oven:

  • It is used for moisture determination of pulp,paper,and paperboard etc.
  • Double walled & heavily insulated.
  • Tempreture range : 50 C to 2500 C
  • Accurancy ±0.5 C.
  • Standard size :24”×24”×24”

Option:

Digital Temperature indicator cum controller.

Features:

  • Easy to maintain
  • Elevated performance
  • Corrosion resistance
Read More...


Yes! I am interested


20,000.00 / Piece

1 Piece (MOQ)

Get Best Price
Business Type Manufacturer, Exporter, Supplier
Application Laboratory Use
Model PAP-3072
Brand Pap-Tech
Dimension 680 mm (Width) x 640 mm (Height) x 520 mm (Depth)
Power Source Electric
Origin India

Preferred Buyer From

Location Worldwide

Description:

We are the leading supplier of Paper INK Proofing Kit made available to our clients at competitive prices.

It is used for visual assessment of color under different lighting conditions.

Features:

  • Cabinet is made out of Powder Coated M.S. Sheet, Inside Color Munsell neutral grey.
  • All tube lights are operated separately by electronic ballast.
  • The electrical circuit is on a tray & is totally separate from the cabinet.
  • Imported Hour Meter is for totalizing the time for Tube Lights.
Read More...


Yes! I am interested


42,000.00 / Piece

1 Piece (MOQ)

Get Best Price
Business Type Manufacturer, Exporter, Supplier
Material Mild Steel
Usage/application Laboratory Uses
Temperature Range Room Temp to 250 Degree Celcius
Body Material Mild Steel
Number Of Shelves 2
No Of Chamber One
Display Type Digital
Brand Pap-Tech
Model No PAP-5053
Accuracy Of Thermostat +/- 1 Deg C to 2 Deg C or less.digita
Features Easy to maintain, Elevated performance, Corrosion resistance
Origin India

Click to view more

Preferred Buyer From

Location Worldwide

Description:

Laboratory Oven:

  • It is used for moisture determination of pulp,paper,and paperboard etc.
  • Double walled & heavily insulated.
  • Tempreture range : 50 C to 2500 C
  • Accurancy ±0.5 C.
  • Standard size :24”×24”×24”

Option:

Digital Temperature indicator cum controller.

Features:

  • Easy to maintain
  • Elevated performance
  • Corrosion resistance
Read More...


Yes! I am interested


28,000.00 / Piece

1 Piece (MOQ)

Get Best Price
Business Type Manufacturer, Exporter, Supplier
Display Type Digital
Automation Grade Manual
Usage/application Used to Accurately Analyze the Given Water & Soil Samples
Brand Pap-tech
Resolution 10 0.01 mS
Temperature Sensor Semi Conductor Type
TDS Range 0-20 ppt
TDS Accuracy ±0.5 % FS ± 1 Digit
DO Range 0-20 ppm
DO Resolution 0.1 ppt
DO Accuracy 0.5 ppm ± 1 Digits
DO Sensor Gold / Silver Aerometric
Turbidity Range 0-1000 NTU
Turbidity Resolution 1 NTU
Turbidity Accuracy ±3 % ± 1 Digits
Sample System 30 mm Clear Glass
Salinity Range 0-50 ppt
Origin India

Click to view more

Preferred Buyer From

Location Worldwide

Description:

The water and soil analysis kits which are used to accurately analyze the given water & soil samples. We have different variants of this product. These instruments areThe water and soil analysis kits which are used to accurately analyze the given water & soil samples. We have different variants of this product. These instruments are successfully serving the specific soil and water analysis requirements of the clients, and offer a cost effective solution to their needs. successfully serving the specific soil and water analysis requirements of the clients, and offer a cost effective solution to their needs.

Features :

  • Temperature Sensor: Semi Conductor Type
  • TDS Range: 0-20 ppt
  • TDS Accuracy: ±0.5 % FS ± 1 Digit
  • DO Range: 0-20 ppm
  • DO Resolution: 0.1 ppt
  • DO Accuracy: 0.5 ppm ± 1 Digits
  • DO Sensor: Gold / Silver Aerometric
  • Turbidity Range: 0-1000 NTU
  • Turbidity Resolution: 1 NTU
  • Turbidity Accuracy: ±3 % ± 1 Digits
  • Sample System: 30 mm Clear Glass
  • Salinity Range: 0-50 ppt
Read More...


Yes! I am interested




Looking for Product Name ?

Close

Raise your Query

Hi! Simply click below and type your query.

Our experts will reply you very soon.

WhatsApp Us